Search results for "Power definitions"
showing 9 items of 9 documents
Measurement of Simplified Single- And Three-Phase Parameters for Harmonic Emission Assessment Based on IEEE 1459-2010
2021
This article investigates the feasibility of using a simplified approach, based on the measurement of power ratio parameters, for harmonic emissions assessment at the point of common coupling (PCC). The proposed approach comes from the common concept of power factor correction and the definitions of the IEEE Std. 1459-2010, where line utilization and harmonic pollution levels are evaluated by means of ratios between the power quantities of the apparent power decomposition. In addition to the IEEE Std. 1459–2010 indicators, in this article, the behavior is studied of additional parameters that are conceptually similar to those defined by the IEEE Std. 1459-2010. The suitability of such param…
A New Measurement Method for the Detection of Harmonic Sources in Power Systems Based on the Approach of the IEEE Std. 1459–2000
2010
In this paper, a novel single-point strategy is proposed for the detection of the harmonic sources in power systems. The method is an improvement of a strategy previously proposed by the authors; it is developed from the IEEE Std 1459-2000 approach and it can be entirely implemented in the time domain, thus simplifying the measurement system. The effectiveness of the proposed method is evaluated by introducing simple decision-making rules and by taking the presence of the measurement transducers into account. Several simulations and experimental tests are presented, showing that the enhanced strategy is able to give an useful information on the detection of the dominant harmonic source upst…
Measurement Uncertainty of Harmonic Emission Indicators based on IEEE Std. 1459-2010
2020
The study presented in this paper is aimed at analyzing the measurement uncertainty impact on the evaluation of some power ratio parameters for harmonic emissions assessment based on IEEE Std. 1459-2010 apparent power decomposition. In addition to power factors for line utilization and harmonic pollution levels evaluation defined in the Standard, the study covers also some new parameters, which have been introduced by the authors as IEEE Std. 1459-2010 power quantities ratios. The measurement of the aforesaid parameters is implemented on a PC-based wattmeter, in order to investigate the measurement uncertainty impact on the evaluation of the power ratios. The obtained results show that, in …
Polluting loads detection in power systems: a decision-making strategy based on nonactive power measurements
2010
In this paper a novel decision-making strategy is proposed for the detection of polluting loads in three-phase power systems. It makes use of simple indices, which are expressed as a function of some nonactive power quantities, previously proposed by the authors and derived from the approach of the IEEE Std. 1459–2000. The decision-making rules for the proposed strategy are presented and discussed, by means of some simulation tests.
A Time-Domain Approach Based on the IEEE Std 1459-2000 for the detection of Loads Producing Harmonic Distortion
2008
This paper presents a novel strategy for the detection of harmonic sources in power systems for both the single-phase and the three-phase systems. It is based on the IEEE Std. 1459-2000 approach and it is based only on the separation of the fundamental components from the harmonic content of voltage and current. The proposed strategy do not require any spectral analysis of voltages and currents and it can be entirely implemented in the time domain. In the paper, the formulation of the novel approach is given and some simulation results are presented.
An enhanced approach based on IEEE 1459 for the detection of disturbing loads in distorted and unbalanced three-phase power systems
2009
This paper presents an enhanced approach for the detection of disturbing loads in distorted and/or unbalanced three-phase power systems in both cases of three and four-wires. It is based on the IEEE Std. 1459-2000 effective apparent power resolution and it requires only the separation of the fundamental components of voltage and current from the remaining harmonic content. In the paper, the formulation of the novel approach is given and some simulation results are presented.
Disturbing loads identification in power systems: a single-point time-domain method based on IEEE 1459-2000
2009
This paper presents a single-point method for the identification of prevailing disturbing loads in power systems for both single-phase and three-phase applications downstream or upstream from the metering section. It is based on the simultaneous measurement of three nonactive power quantities, which are based on the IEEE Std. 1459-2000 approach. The proposed method is only based on the separation of the fundamental components from the harmonic content of voltage and current; thus, it does not require any spectral analysis of the voltages and current. In this paper, the formulation of the proposed method and its time-domain implementation are described; moreover, some simulation results are …
IEEE Std. 1459 power quantities ratio approaches for simplified harmonic emissions assessment
2018
The paper investigates the suitability of using power ratio parameters for harmonic emissions assessment at the point of common coupling (PCC). The study is carried out starting from the IEEE Std. 1459-2010 apparent power decomposition, where power factors are defined for evaluating line utilization and harmonic pollution levels. In addition, the study investigates the behavior of new parameters, which are expressed in terms of ratio between IEEE Std. 1459-2010 power quantities. The study is carried out for both single-phase and three-phase case, also considering the presence of capacitors. ? 2018 IEEE.
Harmonic sources detection in power systems via nonactive power measurements according to IEEE Std. 1459-2010: theoretical approach and experimental …
2010
In this paper an enhanced decision-making strategy is presented for the detection of harmonic sources in power systems able to detect also which is the prevailing nature of the disturbance (nonlinearity or unbalance). It makes use of some simple indices, which are evaluated by means of the measurements of some nonactive power quantities, proposed by the authors and derived from the approach of the IEEE Std. 1459-2010. The decision-making rules for the proposed strategy are presented and discussed by means of simulation and experimental tests. The results obtained are presented, showing the effectiveness of the proposed strategy for the detection of the dominant harmonic source upstream or d…