Search results for "Power definitions"

showing 9 items of 9 documents

Measurement of Simplified Single- And Three-Phase Parameters for Harmonic Emission Assessment Based on IEEE 1459-2010

2021

This article investigates the feasibility of using a simplified approach, based on the measurement of power ratio parameters, for harmonic emissions assessment at the point of common coupling (PCC). The proposed approach comes from the common concept of power factor correction and the definitions of the IEEE Std. 1459-2010, where line utilization and harmonic pollution levels are evaluated by means of ratios between the power quantities of the apparent power decomposition. In addition to the IEEE Std. 1459–2010 indicators, in this article, the behavior is studied of additional parameters that are conceptually similar to those defined by the IEEE Std. 1459-2010. The suitability of such param…

Computer sciencepower measurement02 engineering and technologyPower factorHarmonic distortionlaw.inventionHarmonic analysisElectric power systemControl theorylawpower definitions0202 electrical engineering electronic engineering information engineeringElectrical and Electronic EngineeringInstrumentationuncertainty analysisIEEE Std. 1459-2010020208 electrical & electronic engineeringharmonic emissionAC powerpower qualityPower (physics)CapacitorThree-phaseHarmonicharmonic analysisparameter estimationSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

A New Measurement Method for the Detection of Harmonic Sources in Power Systems Based on the Approach of the IEEE Std. 1459–2000

2010

In this paper, a novel single-point strategy is proposed for the detection of the harmonic sources in power systems. The method is an improvement of a strategy previously proposed by the authors; it is developed from the IEEE Std 1459-2000 approach and it can be entirely implemented in the time domain, thus simplifying the measurement system. The effectiveness of the proposed method is evaluated by introducing simple decision-making rules and by taking the presence of the measurement transducers into account. Several simulations and experimental tests are presented, showing that the enhanced strategy is able to give an useful information on the detection of the dominant harmonic source upst…

EngineeringTotal harmonic distortionbusiness.industrySystem of measurementEnergy Engineering and Power TechnologyAC powerlaw.inventionElectric power systemlawElectrical networkHarmonicElectronic engineeringUpstream (networking)Time domainElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheDetection of harmonic sources harmonic distortion IEEE Std. 1459–2000 power definitions power measurement power quality (PQ)IEEE Transactions on Power Delivery
researchProduct

Measurement Uncertainty of Harmonic Emission Indicators based on IEEE Std. 1459-2010

2020

The study presented in this paper is aimed at analyzing the measurement uncertainty impact on the evaluation of some power ratio parameters for harmonic emissions assessment based on IEEE Std. 1459-2010 apparent power decomposition. In addition to power factors for line utilization and harmonic pollution levels evaluation defined in the Standard, the study covers also some new parameters, which have been introduced by the authors as IEEE Std. 1459-2010 power quantities ratios. The measurement of the aforesaid parameters is implemented on a PC-based wattmeter, in order to investigate the measurement uncertainty impact on the evaluation of the power ratios. The obtained results show that, in …

Measurement uncertaintypower measurement02 engineering and technology01 natural scienceslaw.inventionlaw0202 electrical engineering electronic engineering information engineeringpollutionMedicineuncertainty analysisIEEE Std. 1459-2010Total harmonic distortionbusiness.industry020208 electrical & electronic engineering010401 analytical chemistryWattmeterpower qualityAC power0104 chemical sciencesReliability engineeringPower (physics)harmonic distortionPower definitionsHarmonic pollutionPower ratioharmonic analysisHarmonicMeasurement uncertaintybusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheHarmonic sources2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)
researchProduct

Polluting loads detection in power systems: a decision-making strategy based on nonactive power measurements

2010

In this paper a novel decision-making strategy is proposed for the detection of polluting loads in three-phase power systems. It makes use of simple indices, which are expressed as a function of some nonactive power quantities, previously proposed by the authors and derived from the approach of the IEEE Std. 1459–2000. The decision-making rules for the proposed strategy are presented and discussed, by means of some simulation tests.

Total harmonic distortionEngineeringbusiness.industryControl engineeringFunction (mathematics)AC powerPower (physics)power measurement harmonic distortion power definitions IEEE Std. 1459-2000 harmonic sourcesHarmonic analysisElectric power systemPower system simulationbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

A Time-Domain Approach Based on the IEEE Std 1459-2000 for the detection of Loads Producing Harmonic Distortion

2008

This paper presents a novel strategy for the detection of harmonic sources in power systems for both the single-phase and the three-phase systems. It is based on the IEEE Std. 1459-2000 approach and it is based only on the separation of the fundamental components from the harmonic content of voltage and current. The proposed strategy do not require any spectral analysis of voltages and currents and it can be entirely implemented in the time domain. In the paper, the formulation of the novel approach is given and some simulation results are presented.

Total harmonic distortionEngineeringbusiness.industryPower system harmonicsElectrical engineeringAC powerElectric power systempower measurements harmonic distortion power definitions power qualityElectronic engineeringHarmonicSpectral analysisTime domainbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage2008 IEEE Instrumentation and Measurement Technology Conference
researchProduct

An enhanced approach based on IEEE 1459 for the detection of disturbing loads in distorted and unbalanced three-phase power systems

2009

This paper presents an enhanced approach for the detection of disturbing loads in distorted and/or unbalanced three-phase power systems in both cases of three and four-wires. It is based on the IEEE Std. 1459-2000 effective apparent power resolution and it requires only the separation of the fundamental components of voltage and current from the remaining harmonic content. In the paper, the formulation of the novel approach is given and some simulation results are presented.

Total harmonic distortionEngineeringbusiness.industryharmonic distortion power definitions power quality harmonic sourcesAC powerHarmonic analysisElectric power systemPower system simulationThree-phaseElectronic engineeringHarmonicbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

Disturbing loads identification in power systems: a single-point time-domain method based on IEEE 1459-2000

2009

This paper presents a single-point method for the identification of prevailing disturbing loads in power systems for both single-phase and three-phase applications downstream or upstream from the metering section. It is based on the simultaneous measurement of three nonactive power quantities, which are based on the IEEE Std. 1459-2000 approach. The proposed method is only based on the separation of the fundamental components from the harmonic content of voltage and current; thus, it does not require any spectral analysis of the voltages and current. In this paper, the formulation of the proposed method and its time-domain implementation are described; moreover, some simulation results are …

Total harmonic distortionEngineeringbusiness.industrypower measurements harmonic distortion reactive power power systems power definitions power quality IEEE 1459AC powerPower (physics)Electric power systemHarmonicElectronic engineeringMetering modeUpstream (networking)Time domainElectrical and Electronic EngineeringbusinessInstrumentationSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

IEEE Std. 1459 power quantities ratio approaches for simplified harmonic emissions assessment

2018

The paper investigates the suitability of using power ratio parameters for harmonic emissions assessment at the point of common coupling (PCC). The study is carried out starting from the IEEE Std. 1459-2010 apparent power decomposition, where power factors are defined for evaluating line utilization and harmonic pollution levels. In addition, the study investigates the behavior of new parameters, which are expressed in terms of ratio between IEEE Std. 1459-2010 power quantities. The study is carried out for both single-phase and three-phase case, also considering the presence of capacitors. ? 2018 IEEE.

harmonic sources; IEEE Std. 1459-2010; power definitions; power measurement; power quality020209 energy02 engineering and technologyAC powerAutomotive engineeringlaw.inventionPower (physics)harmonic distortionHarmonic analysisCapacitorHarmonic pollutionlawPower ratio0202 electrical engineering electronic engineering information engineeringHarmonicPoint of common couplingPower measurement harmonic distortion power definitions power quality IEEE Std. 1459-2010 harmonic sourcesSettore ING-INF/07 - Misure Elettriche E ElettronicheMathematics2018 18th International Conference on Harmonics and Quality of Power (ICHQP)
researchProduct

Harmonic sources detection in power systems via nonactive power measurements according to IEEE Std. 1459-2010: theoretical approach and experimental …

2010

In this paper an enhanced decision-making strategy is presented for the detection of harmonic sources in power systems able to detect also which is the prevailing nature of the disturbance (nonlinearity or unbalance). It makes use of some simple indices, which are evaluated by means of the measurements of some nonactive power quantities, proposed by the authors and derived from the approach of the IEEE Std. 1459-2010. The decision-making rules for the proposed strategy are presented and discussed by means of simulation and experimental tests. The results obtained are presented, showing the effectiveness of the proposed strategy for the detection of the dominant harmonic source upstream or d…

power measurement harmonic distortion power definitions IEEE Std. 1459-2010 harmonic sourcesSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct